Prenatal screening



Commonest cause of raised MSAFP = mistaken dates.

Triple screen for antenatal diagnosis of Down's syndrome uses MSAFP, Unconjugated estriol (both are decreased in Down's) and Serum beta HCG (Increased in Down's).

All 3 are decreased in Trisomy 18.

Also remember

Chorionic villus sampling = earliest by 10-12 weeks gestation.
Amniocentesis = earliest by 14-16 weeks gestation.